What we do

We supply and install a range of Fire Doors, Solid Core Doors, Frames and Hardware to residential and commercial buildings.


 We also specialise in retro fitting of metal door frames to new openings or to replace existing non compliant frames. 


We can also supply and fit:

● Fire doors and Solid Core Doors 

●  Fire Rated Locks, Door Closers, Seals, Grilles, Vision Panels and all types of Door Hardware  

● Rated and Non-Rated Frames 

● Frames to New Work & Retro Fit to Existing openings 

● Welding in Hinge and/or Strike Provisions to Repair or Re-hand Existing Frames 

● Passive Fire Protection - Fire-Rated walls/ceilings and Penetrations  

● Fire- Rated Sliders for Large Openings

● Frame and Door Tags and Certifications 

● Signage and Painting  

● Test and Inspection Reports  

Get in touch

Doors

Fire Rated Doors

We supply and install a wide range of 1hr (-60/30) to  4hr (-/240/30) fire rated door sets manufactured in accordance with AS 1905.1 2015 and complying with the BCA.


Our fire doors are suitable for all commercial and residential buildings.

Fire Doors can be supplied with a variety of finishes:

  • Paint grade ply
  • Pre Primed Hardboard
  • MDF
  • Stain grade veneers
  • Zinc sheet
  • Galvanised sheet
  • Stainless steel
  • Colorbond
  • Bolection Mouldings


Optional extras available on fire doors are:

  • Kickplates
  • Non combustible door backing
  • Fire Rated Air Grilles  (up to 2 per door) 450 x 450mm or 600 x 300mm
  • Fire Rated Vision panels  300 x 200mm , 450 x 120mm or 600 x 100mm
  • Preparation for seals
  • Door tunneling to enable cables to be fed from the doors hinge stile to the electric lock


Fire Door FRL:

          FRL on fire doors is related to the wall construction:-

  • Concrete or masonry FRL is up to 4 hours
  • Plaster stud walls up to 2 hours

Fire Door upgrading:

Do you need your doors and/or frames upgrading?


If so, we can modify the existing door frame and upgrade to a fire rated frame by fitting a frame build up and supplying and fitting the correct fire door and door hardware to become compliant. 

Frames

Fire Door Frames

We supply and install metal door frames manufactured from 1.1mm (non-rated) and 1.4mm (fire rated) zinc steel, welded dressed and primed with grey primer ready for final painting. Standard fire door frames are made from zinc steel but  can also be manufactured in Gal or Stainless Steel.

Frames can also be supplied in knockdown form.


Standard door frames are supplied complete with:

  • 3 x Hinge Back plates for screw fix hinges
  • Standard universal striker positioned 1032mm from bottom of door frame
  • Removable spreader bars


 AVAILABLE EXTRAS  

 

  • Additional hinge preps
  • Preparation to accommodate an electric strike or a power transfer cable device
  • Preparation to accommodate top latches or a reed switch
  • Preparation for concealed door closers 
  • Various fixing methods such as: - Stud Brackets, Stud Straps & Counter sunk holes (retro fit)
  • Single, Pair, Transom, Mullion or Interconnecting frame combinations

Custom Made Door Frames

We can supply and install custom made fire door frames. 


We would site measure and tailor the frame to suit the size, fixing method, frame profile and other custom configuration that may be required. Such as fixed or removable overhead transom, mullion frames, unequal pairs, access panels, four sided frames, to name a few.


Lead time on fire door frames are 10-14 working days depending on workload at the time an order is placed.

Frame Upgrading

It is common to have non rated doors in buildings that need to be converted to fire rated doors. This could be due to renovations, change of regulations or original installation of door and frames being incorrect.


Usually existing frames do not need to be removed, just upgraded to a fire door frame so that fire doors can be fitted.

With single doors requiring a 2 hour FRL, we can upgrade to a fire rated frame by fitting a metal door frame build up.


We can also upgrade double door frames by welding tailored frame sections to the existing door frame. Again, the maximum FRL is 2 hours.

Hardware

Fire Door Hardware

 We supply and fit a range of Fire Rated Locks, Door Closers, Seals, Grilles, Vision Panels and all types of Door Hardware.


To comply with AS1905.1, all hinged fire doors must be self closing and self latching. To achieve this, fire doors must be fitted with the correct fire rated hardware, comprising heavy duty hinges, latching device and door closer. 

Pairs of fire doors will require a sequential closing device and latching device as well as a closer on each leaf. 


We can also supply and fit smoke seals if necessary depending on the buildings requirements.



Copyright © 2019 BJM Fire Door Installations - All Rights Reserved.

ABN 54 162 589 326 Lic No 312258C

  • Home
  • What we do
  • Who we service
  • Where we go
  • Who we are
  • What we've done
  • Contact us

Cookie Policy

This website uses cookies. By continuing to use this site, you accept our use of cookies.

Accept & Close